| Model | Capacity | Air | Dimension (mm) | Weight | |||||
| m³/min | CFM | Connection | A | B | C | D | E | (kg) | |
| RSG-**-0017G/V2 | 1 | 35 | Rc1/2" | 89 | 40 | 158 | / | 95 | 1.1 |
| RSG-**-0030G/V2 | 1.8 | 64 | Rc1/2" | 89 | 40 | 192 | / | 130 | 1.5 |
| RSG-**-0058G/V2 | 3.6 | 127 | Rc3/4" | 120 | 55 | 252 | / | 172 | 2.5 |
| RSG-**-0080G/V2 | 4.8 | 169 | Rc1" | 120 | 55 | 352 | / | 272 | 3.2 |
| RSG-**-0145G/V2 | 8.7 | 307 | Rc1-1/2" | 120 | 55 | 352 | / | 272 | 3.2 |
| RSG-**-0220G/V2 | 13.2 | 466 | Rc2" | 162 | 64 | 468 | 180 | 320 | 6.6 |
| RSG-**-0330G/V2 | 20 | 706 | Rc2" | 162 | 64 | 742 | 180 | 625 | 10.9 |
| RSG-**-0430G/V2 | 25.8 | 911 | Rc3" | 200 | 78 | 500 | 180 | 650 | 12.9 |
| RSG-**-0620G/V2 | 40 | 1412 | Rc3" | 200 | 78 | 757 | 180 | 650 | 17.5 |
| RSG-**-0830F/V2 | 50 | 1766 | DN100 | 493 | 263 | 1119 | 220 | 650 | 115 |
| RSG-**-1000F/V2 | 60 | 2119 | DN100 | 493 | 263 | 1119 | 220 | 650 | 115 |
| RSG-**-1200F/V2 | 70 | 2472 | DN125 | 617 | 290 | 1179 | 220 | 650 | 145 |
| RSG-**-1300F/V2 | 80 | 2825 | DN125 | 617 | 290 | 1179 | 220 | 650 | 150 |
| RSG-**-1950F/V2 | 120 | 4237 | DN150 | 617 | 299 | 1206 | 220 | 650 | 195 |
| RSG-**-2500F/V2 | 150 | 5297 | DN200 | 666 | 343 | 1354 | 220 | 650 | 240 |
| RSG-**-3250F/V2 | 200 | 7062 | DN200 | 740 | 368 | 1459 | 220 | 650 | 380 |
| RSG-**-4650F/V2 | 280 | 9887 | DN250 | 800 | 420 | 1583 | 220 | 650 | 450 |
| RSG-**-5200F/V2 | 312 | 11017 | DN250 | 800 | 420 | 1583 | 220 | 650 | 455 |
| RSG-**-7800F/V2 | 468 | 16525 | DN300 | 906 | 476 | 1646 | 220 | 650 | 850 |
1 Micron Compressed Air Filter usually adopts high-efficiency filter media, such as multi-layer fiber filter or special filter material, to achieve good filtering effect. Its structure is strong and durable, can withstand high pressure and flow, and adapt to various complex working environments.
Filter Specification
Oil mist removal filter: grade AO,AA and AX
Particle removal filter: grade AR and AAR
Oil vapour removal filter: grade ACS
| Grade | Micron Rating | Residual Oil Mist | Dry Δp Kpa | Wet Δp Kpa | Element Change | Precede with |
| (μm) | (mg/m³) | Interval | Filtration Grade | |||
| AO | 1 | 0.6 | 7 | 14 | 12 months | WS |
| AA | 0.01 | 0.01 | 10 | 20 | 12 months | AO |
| AR | 1 | / | 7 | / | 12 months | / |
| AAR | 0.01 | / | 10 | / | 12 months | AR |
| AX | 0.01 | 0.001 | 20 | 40 | 12 months | AA |
| ACS | / | 0.003 | 7 | / | 1000 hours | AA |
This filter plays a key role in many fields. In the electronics manufacturing industry, pure compressed air is essential for precision operations in chip production and circuit board assembly. The 1 micron filtration accuracy can effectively prevent the influence of tiny particles on product quality. In the pharmaceutical and medical fields, it helps to ensure the sterility and purity of compressed air, ensure the safety of drug production and the normal operation of medical equipment. In automotive manufacturing, high-precision compressed air can be used in processes such as painting and parts assembly to improve the appearance quality and performance of products.
1 Micron Compressed Air Filter is also easy to install and maintain. It can be easily integrated with the existing compressed air system, and the operation of regular replacement of filter elements is relatively simple, which can reduce the maintenance cost and downtime of equipment.
Correction Factors
Actual Capacity (m³/min) = Nominal Capacity × KA
| Working Pressure (KA) | Mpag | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 |
| psig | 15 | 29 | 44 | 58 | 73 | 87 | 102 | 116 | |
| CFP | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1 | 1.07 | |
| Mpag | 0.9 | 1 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.6 | |
| psig | 131 | 145 | 160 | 174 | 189 | 203 | 218 | 232 | |
| CFP | 1.13 | 1.2 | 1.25 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |