Reliable Design
Patented Process of RISHENG;
- Non-electric Operation: Operates without electricity, making it suitable for remote or hazardous locations.
- Low Maintenance: Simple design with no moving parts ensures minimal maintenance and long service life.
- Corrosion Protection: Helps protect downstream equipment and piping from rust and corrosion caused by moisture.
- Pressure Range: Suitable for use in systems with varying pressure levels.
- Compact Design: Easy to install in limited spaces or retrofit into existing systems.
Various control options
Standard configuration is using reliable PLC controller.
Optional Siemens and ABB brand PLC or touch screen and etc.
We can meet various customer requirements for communication, connecting RS485 I/O , Profibus or Modbus to Ethernet.
Applications
- Oil & Gas Industry: Used in field operations to dry compressed air for instrumentation and controls.
- Mining & Construction: Ideal for portable air compressor systems operating in rugged environments.
- Pipeline Services: Common in pipeline purging and pigging operations where moisture control is critical.
- Manufacturing Plants: Supports operations requiring dry air but not extremely low dew points.
- Remote Installations: Effective in off-grid locations due to its passive design.
Technical Specification of RSXB-150~RSXB-2000 Series Blower Purge Regeneration Compressed Air Dryer
| Model | Air | Capacity | Installed | Demension mm | Weight | Recommended | Recommended | |||
| Connection | m³/min | CFM | Power (kW) | L | W | H | (kg) | Pre-Filter Model | After-Filter Model | |
| RSXB-150 | DN50 | 15 | 530 | 11.4 | 1602 | 926 | 2324 | 1250 | RSG-AA-0330G/V2 | RSG-AR-0330G/V2 |
| RSXB-180 | DN65 | 18 | 636 | 20.5 | 1899 | 1100 | 2284 | 1400 | RSG-AA-0330G/V2 | RSG-AR-0330G/V2 |
| RSXB-220 | DN65 | 22 | 777 | 20.5 | 1959 | 1130 | 2458 | 1530 | RSG-AA-0430G/V2 | RSG-AR-0430G/V2 |
| RSXB-250 | DN65 | 25 | 883 | 20.5 | 2009 | 1110 | 2559 | 1715 | RSG-AA-0430G/V2 | RSG-AR-0430G/V2 |
| RSXB-330 | DN80 | 33 | 1165 | 23.5 | 2083 | 1212 | 2569 | 2100 | RSG-AA-0620G/V2 | RSG-AR-0620G/V2 |
| RSXB-440 | DN100 | 44 | 1554 | 34.5 | 2750 | 1274 | 2613 | 2690 | RSG-AA-0830F/V2 | RSG-AR-0830F/V2 |
| RSXB-500 | DN100 | 50 | 1766 | 42 | 2835 | 1284 | 2693 | 2980 | RSG-AA-1000F/V2 | RSG-AR-1000F/V2 |
| RSXB-600 | DN100 | 60 | 2119 | 42 | 2865 | 1341 | 2648 | 3390 | RSG-AA-1000F/V2 | RSG-AR-1000F/V2 |
| RSXB-700 | DN125 | 70 | 2472 | 58 | 2965 | 1691 | 2744 | 4190 | RSG-AA-1200F/V2 | RSG-AR-1200F/V2 |
| RSXB-800 | DN125 | 80 | 2825 | 58 | 3103 | 1617 | 2869 | 4600 | RSG-AA-1300F/V2 | RSG-AR-1300F/V2 |
| RSXB-900 | DN150 | 90 | 3178 | 86.5 | 3900 | 2189 | 2775 | 5800 | RSG-AA-1950F/V2 | RSG-AR-1950F/V2 |
| RSXB-1000 | DN150 | 100 | 3531 | 86.5 | 4230 | 2194 | 2872 | 6300 | RSG-AA-1950F/V2 | RSG-AR-1950F/V2 |
| RSXB-1200 | DN150 | 120 | 4237 | 107 | 4400 | 2204 | 2855 | 6800 | RSG-AA-1950F/V2 | RSG-AR-1950F/V2 |
| RSXB-1500 | DN200 | 150 | 5297 | 130 | 5016 | 2503 | 2947 | 9200 | RSG-AA-2500F/V2 | RSG-AR-2500F/V2 |
| RSXB-2000 | DN200 | 200 | 7062 | 165 | 5516 | 2518 | 3077 | 11700 | RSG-AA-3250F/V2 | RSG-AR-3250F/V2 |
|
Rated Conditions |
Working Range |
Avaliable |
![]() |
|
Working pressure: 0.7MPag / 100psig |
Max. working pressure: 1.0MPag / 145psig |
Higher pressure above 1.0MPag / 145psig |
|
|
Inlet temp: 38℃ / 100℉ |
Max. inlet temperature: 45℃ / 113℉ |
Zero purge from model RSXB-180 |
|
|
Ambient temp: 38 ℃ / 100℉ |
Max. ambient temperature: 40℃ / 104℉ |
PDP -20℃ / -4℉ and -70℃ / -100℉ |
|
|
PDP: -40℃ / -40℉ |
Higher capacity |
||
|
Stainess steel vessel or piping |
|||
|
GB, ASME, PED, etc. |
Correction Factors
Actual Capacity (m³/min) = Nominal Capacity × KA × KB
| Working Pressure (KA) | Mpag | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1 |
| Psig | 73 | 87 | 100 | 116 | 131 | 145 | |
| CFP | 0.75 | 0.87 | 1 | 1.13 | 1.25 | 1.37 |
| Inlet Temperature (KB) | ℃ | 35 | 38 | 40 | 42 | 45 |
| ℉ | 95 | 100 | 104 | 108 | 113 | |
| CFT | 1.18 | 1 | 0.9 | 0.81 | 0.69 |